Back to Explore

Bubba Que Trinity

8094 Little Road, New Port Richey FL 34654

Parcel map
Mapbox
© Mapbox © OpenStreetMap

Permit Details

a first-time interior build-out of an existing cold gray shell commercial unit for a new restaurant occupancy Bubba Que Trinity. The space currently consists of exterior walls and roof structure only, with no interior slab or tenant improvements. Scope of work includes: Installation of new concrete slab and interior floor system. Construction of new interior non-structural partitions and framed walls. Installation of two rooftop HVAC units with new ductwork, ventilation systems, and controls. Installation of two Type I commercial kitchen exhaust hoods with roof-mounted exhaust fan, make-up air unit, and grease duct system. Installation of new plumbing systems including water service distribution, sanitary waste and vent piping, grease waste connection, and required fixtures. Installation of natural gas piping for commercial kitchen equipment. Installation of new electrical service distribution, panels, branch circuits, lighting, emergency lighting, and equipment connections. Installation of required restroom exhaust systems and mop sink exhaust. Installation of interior finishes including tile flooring, wall finishes, ceiling systems, and paint. Exterior penetrations for mechanical exhaust and utility connections as shown in the approved plans. No modifications to primary structural framing or load-bearing exterior walls are proposed except as detailed in the engineered permit drawings. All work shall comply with the current Florida Building Code, Florida Fire Prevention Code, and applicable local and health department regulations.


Filed Date
Feb 23, 2026
Type of Work
Standard New Construction
Estimated Construction Cost
$430,000
Building Size (sq ft)
9,963
Floors
1
Owner
Npr Building B Lllp
Contractor
The Jones Crew Builders INC
Development
TEST
Technical details
Use Classification
Assembly
Group Type
Restaurants, Cafeterias & similar dining facilities (including associated commercial kitchens)
Occupancy Load
89
Licensed Professional
Jordan Hunter Jones(CBC1259850)

Permit Progress

Inactive

Permit is withdrawn, expired, or cancelled.

Last status change Feb 25, 2026

Pipeline

Application
Plans Review
Pre-Approval
Issuance
Inspection
Final

Parcel Information

Parcel Number
26 25 16 0120 00000 0020
Lot Size
1.53 acres
Zoning
C2-100
Land Use
Stores
Report an issue